6.0 SYSTEM DETAILS
6.1 Information
1. The Main Combi 24 Combination Boiler is a Water
Byelaws Scheme - Approved Product.
To comply with the Water Byelaws your attention is
drawn to the following installation requirements and notes
(IRN).
a) IRN 001 - See text of entry for installation
requirements and notes.
b) IRN 302 - Byelaw 14.
2. Reference to the WRc publications, Water fittings and
materials directory and Water supply byelaws guide give
full details of byelaws and the IRNs.
6.2 Central Heating Circuit
1. The appliance is suitable for fully pumped SEALED
SYSTEMS ONLY.
Treatment of Water Circulating Systems
All recirculatory water systems will be subject to
corrosion unless an appropriate water treatment is
applied. This means that the efficiency of the system will
deteriorate as corrosion sludge accumulates within the
system, risking damage to pump and valves, boiler noise
and circulation problems.
When upgrading existing systems that exhibit evidence
of sludging, it is advisable to clean the system prior to
treatment in order to remove any sludge and reduce the
likelihood of these deposits damaging new components.
When fitting new systems flux will be evident within
the system, which can lead to damage of system
components.
All systems must be thoroughly drained and flushed
out. The recommended flushing and cleansing agents
are Betz-Dearborn Sentinel X300 or X400 and Fernox
Superfloc Universal Cleanser which should be used
following the flushing agent manufacturers instructions.
System additives - corrosion inhibitors and flushing
agents/descalers should be suitable for aluminium and
comply to BS7593 requirements. The only system
additives recommended are Betz-Dearborn Sentinel
X100 and Fernox-Copal which should be used following
the inhibitor manufacturers instructions.
Failure to flush and add inhibitor to the system
may invalidate the appliance warranty.
It is important to check the inhibitor concentration
after installation, system modification and at every
service in accordance with the manufacturers
instructions. (Test kits are available from inhibitor
stockists.)
For information or advice regarding any of the above
contact Technical Enquiries.
6.3 Bypass
1. The boiler is fitted with an automatic integral bypass.
6.4 System Control
1. The boiler is designed for use in a heating system that
incorporates external controls, i.e. a minimum of a timer
device.
2. An integral electro-mechanical or electronic timer is
available as an optional extra.
3. For optimum operating conditions and maximum
economy the fitting of a programmable thermostat is
recommended.